Home
About
News
Gallery
Products:
Generators
Transferswitches
Fuel Tanks
Trailers
Controllers
Current Stock List
Product Literature
Parts
Service
Trouble Shooting
Warranty
Show And Fair Schedule
Contact Us
Dealer Locator




|
Products
Marine Diesel Generators: 9NY
Standby Rating 60 Hz : 9kW (9kVA)
Prime Rating 60 Hz : 8kW (8kVA)
Standard Features
• Analog 200 Remote Control Panel
• 10' Extension Harness
• Aqua Shield™ Patented Ex. Manifold Cover
• Marine Grade Epoxy Paint
• Oil Drain Kit (Valve Type w/ Safety Lock)
• Washable Long-Life Air Filter
• Buddy Box (Spare Parts Kit)
• ABS Molded Belt Guard
• Coolant Overflow Bottle
• Rubber Isolation Mounts
• Stainless Steel Drip Pan
• Single Lifting Point
• Hand Built In The USA
• Prototype And Production Tested
• Meets or Exceeds Tier 2 Nonroad Emissions
• 5 Year 5,000 Hour Warranty |
Some options may be shown
|
Generator Specifications: |
|
Manufacturer
Type
Exciter Type
Leads: Quantity
Voltage Regulator
Insulation Material
Temperature Rise
Bearing Type
Coupling
Voltage Regulation
Phase Type
Power Factor
Power Rating At 60hz
Power Rating At 50hz
Mainline Breaker (Amps) *Optional |
SKG
4 Pole
Brushless
4
AVR
H Type
105°C
Sealed
Direct Bolt-Up
1%
1
1.0
9 kW (9kVA)
7.5 kW (7.5kVA)
30 For 60hz, 25 For 50hz
|
Amps @ 120 Volts 60hz
Amps @ 240 Volts 60hz
Amps @ 120 Volts 50hz
Amps @ 240 Volts 50hz
|
75
37.5
62
31 |
Manufacturer
Engine: Model Type
Cylinder Arrangment
Displacment
Bore
Stroke
Compression Ratio
Rated RPM 60 hz
Rated RPM 50 hz
Max Power At Rated RPM (60hz)
Max Power At Rated RPM (50hz)
Cylinder Head Material
Block Material
Governor Type
Frequency Regulation
Air Filter Type |
Yanmar
3TNE74
3 In Line 4 Cycle
68.1 cu.in. (1116 cc)
2.99 in. (75.9mm)
3.23 in. (82mm)
23.5:1
1800
1500
14.3 bhp
11.9 bhp
Cast Iron
Cast Iron
Mechanical
3-5%
Replaceable Element |
Engine Electrical System: |
|
Ignition System
Starter System Voltage (DC)
Battery Recommendation (CCA)
Battery Voltage (DC)
Starter kW |
Electric
12V
500
12V
1 |
Fuel Shutoff Solenoid
Fuel Pump Priming
Fuel Pump
Fuel Type
Fuel Pump Lift
Fuel Line Supply
Fuel Line Return |
Electric
Electric
Mechanical
#2 Diesel
3.28 ft. (1m)
5/16 in. (7.9mm)
5/16 in. (7.9mm)
|
100% Load At 60hz
75% Load At 60 hz
50% Load At 60 hz |
.90 gph. (3.4 Lph)
.69 gph. (2.6 Lph)
.50 gph. (1.9 Lph) |
100% Load At 50hz
75% Load At 50 hz
50% Load At 50 hz |
.75 gph. (2.8 Lph)
.57 gph. (2.1 Lph)
.42 gph. (1.6 Lph) |
Manifold
Engine Coolant Capacity
Heat Exchanger Type
Raw Water Pump Inlet
Raw Water Pump Type
Raw Water Pump Flow Rate
Engine Water Pump Type
Fan Diameter*
Fan & Alternator (hp)*
Fan Type
Fan Rotation
* Used only on sound enclosed models
|
Water Jacketed
.951 qts. (.89 L)
3 in. (76.2mm) 2 Pass Cupronickel
5/8 in. (15.87mm)
Belt Driven
8 gpm. (30.28 Lph)
Centrifugal
9.5 in. (241.3mm)
.5
5 Blade Pusher
Clockwise
|
Type
Engine Oil Capacity With Filter
Oil Filter Type
|
Full Pressure
3.7 qts. (3.5 L)
Spin-On
|
Exhaust Type
Max Allowable Back Pressure
Exhaust Outlet Size
|
Water Cooled
3.48 in. hg (8.8cm hg)
2 in. (5cm)
|
Engine Combustion Air Intake Requirements
Generator End Cooling Requirements
Sound Shield Air Space Requiremants
|
29 cfm. (8.8 cmm)
250 cfm. (76.2 cmm)
4 in. (10.1cm)
|
dB(A) Without Sound Shield
Load
3'
10'
21' |
100%
83
80
78 |
75%
82
79
74 |
50%
81
79
73 |
dB(A) With Sound Shield
Load
3'
10'
21' |
100%
70
66
62 |
75%
69
65
61 |
50%
69
64
51 |
Open Unit:
Length - in(cm)
Width - in(cm)
Height - in(cm)
Dry Weight - lbs.(kg)
Wet Weight - lbs.(kg) |
28.5 (72.4)
18 (45.7)
22 (55.9)
433 (196.4)
443 (200.9)
|
Enclosed Unit:
Length - in(cm)
Width - in(cm)
Height - in(cm)
Dry Weight - lbs.(kg)
Wet Weight - lbs.(kg) |
34 (71.1)
20 (50.8)
23 (58.4)
498 (225.9)
508 (230.4)
|
|
Please Note: While every attempt is made to ensure the information on this site is accurate, this data is provided for information purposes only and is subject to change without notice.
|
|